 "version": "2026-10-20",
 "license": "Dimension sheets: CC BY 4.0. Standard and published-size files: CC BY 4.0. Xem Studio's own designs (files_license = Xem Studio Design License): free to use and sell things from, not to redistribute as files — https://xemstudio.com/license/. Other publishers' files: their own license, linked beside them.",
 "slug": "tri-clamp-clamp-on-water-jacket-14mm",
 "name": "Tri-clamp water jacket: 14 mm clamp-on halves for 2 in tube",
 "kind": "hardware",
 "category": "Hardware",
 "group": "Heat transfer",
 "year": null,
 "question": "What water jacket clamps onto a 2 inch tri-clamp tube?",
 "tags": [
  "thermoacoustic",
  "water jacket",
  "cooling",
  "heat exchanger",
  "tri-clamp",
  "long earth society"
 ],
 "aliases": [
  "thermoacoustic water jacket",
  "tri clamp water jacket",
  "cold heat exchanger cooling thermoacoustic",
  "clamp on water cooling 2 inch tube"
 ],
 "overall_mm": {
  "length": null,
  "width": null,
  "height": null
 },
 "official_cad": false,
 "xem_status": "free-files",
 "les": true,
 "free_files": 1,
 "url": "https://xemstudio.com/objects/tri-clamp-clamp-on-water-jacket-14mm/",
 "sheet_txt": "https://xemstudio.com/objects/tri-clamp-clamp-on-water-jacket-14mm/sheet.txt",
 "sheet": {
  "basis": "Bore = ASME BPE 2 in tube OD Ø50.8; length and start position from the exchanger positions in tools/gen_ta_family.py; ISO 273 medium clearance for M4",
  "overall_mm": {
   "length": null,
   "width": null,
   "height": null
  },
  "notes": [
   "A short jacket for the one place a thermoacoustic core must be held at room temperature: the tube wall over an ambient heat exchanger. It is 14 mm long so it covers the 10 mm exchanger and stops before the regenerator or stack; it starts 9.35 mm from the clamp face, 0.5 mm clear of the clamp.",
   "Two identical halves close on the tube with one M4 × 25 and nut each side. Each half has its own closed water chamber (6 mm deep, 11 long) and two Ø6 hose spigots, in and out; run the two halves in series with a short hose, or in parallel.",
   "The inner wall is the heat path: tube wall, jacket wall, water. What it is made of is the builder's choice; the file is the geometry.",
   "Fits: bore clamps on the tube OD (the 1 mm split is the take-up); spigots are a press fit in 6 mm ID hose; ear holes are M4 clearance."
  ],
  "table": {
   "columns": [
    "feature",
    "value"
   ],
   "rows": [
    [
     "bore",
     "Ø50.8 (tube OD)"
    ],
    [
     "length",
     "14"
    ],
    [
     "outside",
     "Ø68.8"
    ],
    [
     "chamber",
     "6 deep × 11 long, per half"
    ],
    [
     "spigots",
     "2 per half, Ø6 × 10, Ø4 bore"
    ],
    [
     "bolts",
     "M4 × 25 + nut, one each side"
    ]
   ]
  }
 },
 "sheet_text": "Tri-clamp water jacket: 14 mm clamp-on halves for 2 in tube — dimension sheet\nSource: Xem Studio, https://xemstudio.com/objects/tri-clamp-clamp-on-water-jacket-14mm/  (sheet CC BY 4.0; files Xem Studio Design License, https://xemstudio.com/license/)\nBasis: Bore = ASME BPE 2 in tube OD Ø50.8; length and start position from the exchanger positions in tools/gen_ta_family.py; ISO 273 medium clearance for M4\nCatalog version: 2026-10-20\n\nSizes: see table below\n- A short jacket for the one place a thermoacoustic core must be held at room temperature: the tube wall over an ambient heat exchanger. It is 14 mm long so it covers the 10 mm exchanger and stops before the regenerator or stack; it starts 9.35 mm from the clamp face, 0.5 mm clear of the clamp.\n- Two identical halves close on the tube with one M4 × 25 and nut each side. Each half has its own closed water chamber (6 mm deep, 11 long) and two Ø6 hose spigots, in and out; run the two halves in series with a short hose, or in parallel.\n- The inner wall is the heat path: tube wall, jacket wall, water. What it is made of is the builder's choice; the file is the geometry.\n- Fits: bore clamps on the tube OD (the 1 mm split is the take-up); spigots are a press fit in 6 mm ID hose; ear holes are M4 clearance.\n\nfeature  value\nbore  Ø50.8 (tube OD)\nlength  14\noutside  Ø68.8\nchamber  6 deep × 11 long, per half\nspigots  2 per half, Ø6 × 10, Ø4 bore\nbolts  M4 × 25 + nut, one each side\n\nFiles elsewhere (not hosted by Xem Studio; license as stated by the publisher):\n- Long Earth Society: Engine builds — web, video — LES site — https://longearthsociety.com/engineering/\n\nFree files (Xem Studio Design License, Xem Studio; STEP + STL, 1 parts): https://xemstudio.com/files/hardware/tri-clamp-clamp-on-water-jacket-14mm/index.json\nAPI: https://xemstudio.com/api/geometry?object=tri-clamp-clamp-on-water-jacket-14mm\n",
 "sources": [
  {
   "publisher": "Long Earth Society",
   "title": "Engine builds",
   "url": "https://longearthsociety.com/engineering/",
   "formats": [
    "web",
    "video"
   ],
   "license": "LES site",
   "license_verified": true,
   "hosted": false
  }
 ],
 "xem": {
  "status": "free-files",
  "sheet_free": true,
  "mesh_price_usd": null,
  "step_price_usd": null,
  "tolerance_mm": null
 },
 "related": [
  "tri-clamp-jacket-shell",
  "tri-clamp-parallel-plate-heat-exchangers",
  "tri-clamp-bore-spacers-2in",
  "silicone-tube"
 ],
 "fits": [],
 "dimensions": "exact (nominal, no tolerance added)",
 "dimension_rule": "All geometry on Xem Studio is exact (nominal, true size) with no tolerance added. Where a part meets another part, the object lists its mating features (feature, exact size, what it mates with, fit class: press, slide, run, socket, clamp or designed). Apply your process's allowance to those features only; 'designed' gaps are part of the design and stay as drawn. Typical accuracy by process and ISO 286 fits: https://xemstudio.com/tolerances/",
 "mating": [
  {
   "feature": "bore",
   "exact": "Ø50.8",
   "mates": "2 in tube OD",
   "fit": "clamp",
   "files": "ta-jacket-half-"
  },
  {
   "feature": "split",
   "exact": "1.0 total (0.5 per half)",
   "mates": "the other half",
   "fit": "clamp",
   "files": "ta-jacket-half-"
  },
  {
   "feature": "ear holes",
   "exact": "Ø4.5",
   "mates": "M4 clearance (ISO 273 medium)",
   "fit": "designed",
   "files": "ta-jacket-half-"
  },
  {
   "feature": "hose spigots",
   "exact": "Ø6 × 10, Ø4 bore",
   "mates": "6 mm ID hose",
   "fit": "press",
   "files": "ta-jacket-half-"
  },
  {
   "feature": "start from the clamp face",
   "exact": "9.35",
   "mates": "clamp reaches 8.83 from the face",
   "fit": "designed",
   "files": "ta-jacket-half-"
  }
 ],
 "fit_classes": {
  "press": "stays put: pin, tube, bearing or magnet held by interference. ISO 286 equivalent: H7/p6 (locational interference) or tighter.",
  "slide": "assembles by hand and is held by a grub, pinch or clamp: shaft in a hub, rod in a socket, spigot in a bore. ISO 286 equivalent: H7/g6 or H7/h6.",
  "run": "turns or slides in use: pin in a link, rod through a guide. ISO 286 equivalent: H8/f7 (close running).",
  "socket": "large sliding fit: syringe barrel, sleeve, bobbin in a bore. ISO 286 equivalent: H9/d9 (free running) or looser.",
  "clamp": "split part that closes on the mating part with screws: make it at size.",
  "designed": "a gap that is part of the design (piston fit option, displacer gap, air gap): do not change."
 },
 "faq": [
  {
   "q": "Why only 14 mm long?",
   "a": "The ambient exchanger is 10 mm; a longer jacket would also cool the regenerator or stack next to it and take away the temperature difference the engine runs on."
  },
  {
   "q": "Can I use the 56 mm jacket instead?",
   "a": "Not on these cores: it would reach the hot exchanger. It suits the Stirling hot and cold spools."
  }
 ],
 "files_license": {
  "name": "Xem Studio Design License",
  "holder": "Xem Studio",
  "url": "https://xemstudio.com/license/",
  "note": "Xem Studio's own design: free to use, print, modify and sell things made from it; not to be republished or redistributed as files."
 },
 "offers": [
  {
   "file": "ta-jacket-half-2in-14",
   "formats": [
    "step",
    "stl"
   ],
   "price_usd": 0,
   "license": "Xem Studio Design License",
   "step": "https://xemstudio.com/files/hardware/tri-clamp-clamp-on-water-jacket-14mm/ta-jacket-half-2in-14.step",
   "stl": "https://xemstudio.com/files/hardware/tri-clamp-clamp-on-water-jacket-14mm/ta-jacket-half-2in-14.stl",
   "note": "water-jacket half for the 2 in tube (Ø50.8) × 14: walls 1.5, chamber 6 deep, ends 1.5, split wall 1.5; ears x ±33–47 with Ø4.5 at ±41; two Ø6 × 10 spigots (Ø4 bore) at 60° and 120°"
  }
 ],