Two-bolt high-pressure clamps for 10 and 12 in tri-clamp joints — dimension sheet Source: Xem Studio, https://xemstudio.com/objects/sanitary-clamp-bolted-clamps-10-12in/ (sheet CC BY 4.0) Basis: Groove as the site's tri-clamp clamps (the ISO 2852 rim's 20° back cone mirrored, contact after 0.4, 0.6 squeeze), on the 10 / 12 in rims; two halves, one M8 bolt at each split Catalog version: 2026-10-20 Sizes: see table below - Published ratings (Steel & O'Brien, psi at 70 °F / 250 °F): 10 in 13MHP high-pressure 200 / 125, 13ASME double-bolt 161 / 145, 13MHHM wing-nut 75 / 40; 12 in 150 / 100, 102 / 92, 50 / 25. Holland and Shaw rate their hinged wing-nut clamps lower still (10 in 40 / 30 psi). A wing-nut clamp is not a pressure clamp at these sizes. - This clamp is a Xem Studio design, not a copy of any of those: the end load on a 10 in joint at 6 bar gauge is 32.1 kN (pressure out to the groove diameter), the 20° groove turns it into a hoop tension of 1859 N at each split (F tan 20° / 2π), 51 MPa on an M8's stress area before the seating load. The section behind the groove is 6 mm; size the clamp's own material for that tension at the joint's temperature, or use a rated commercial high-pressure clamp of the same rim size. - Each half: lug at each end with an M8 clearance hole (Ø9, ISO 273 medium) along the split; the +x lug has a hex pocket 13 AF × 5.3 deep on its outer face that holds an ISO 4017 M8 hex head (s 13, k 5.3) so the bolt cannot turn, the −x lug is the plain hole. The two halves are the same part turned 180°, so at each bolt the head sits in one half's pocket and the M8 nut (ISO 4032) runs down on the other half's plain lug. Tighten evenly until the halves just meet. size_in clamp_od_mm width_mm bolt_spacing_mm bolts 13MHP_psi_70F_250F 13MHHM_psi_70F_250F 10 282.5 19.43 298.5 2 × M8 × 40 hex head (ISO 4017) + nuts 200 / 125 75 / 40 12 333.3 19.43 349.3 2 × M8 × 40 hex head (ISO 4017) + nuts 150 / 100 50 / 25 Files elsewhere (not hosted by Xem Studio; license as stated by the publisher): - Steel & O'Brien: Sanitary products catalog 2024: 16AMP end caps 10 / 12 in (A 0.480, B 10.570 / 12.570 in); L14AM7 ferrules 1.500 in; clamp ratings 13MHHM, 13MHP, 13ASME — PDF — publisher's catalogue; dimensions cited, nothing copied — https://www.steelobrien.com/wp-content/uploads/2024/03/Sanitary-2024-FINAL.pdf - Holland Applied Technologies: Sanitary tri-clamp fittings: EG14AM7 ferrules 8 / 10 / 12 in (1.500, bore 9.732 / 11.732 in, tube 10.000 / 12.000 in); EG16A caps (10.570 / 12.570 in) — PDF — publisher's catalogue; dimensions cited, nothing copied — https://hollandapt.com/wp-content/uploads/2022/12/Sanitary-Tri-Clamp-Fittings.pdf - Shaw Stainless & Alloy: Sanitary clamp data sheet: EG14AM7 ferrules (bore 9.732 / 11.732 in), EG16A caps 10.570 / 12.570 in, 13MHHM ratings — PDF — publisher's data sheet; dimensions cited, nothing copied — https://stainlessandalloy.com/pdf/data-sheets/sanitary-clamp-data-sheet.pdf - ISO (via iTeh sample): ISO 2852 clamp liners: face profile (2.85 rim, flat face with the gasket groove: K 1.6, R3 1.2, 23°, P2 0.8; 20° back) and Type B gasket — PDF — standard excerpt; dimensions are facts — https://cdn.standards.iteh.ai/samples/7850/eb49c396488d408c8ced3e2961d76cf3/ISO-2852-1974.pdf - McGraw-Hill: Young & Budynas, Roark's Formulas for Stress and Strain, 7th ed.: Table 8.1 (fixed–guided beam), Table 11.2 (circular plates under uniform pressure) — book — formulas are facts [verify license at link] — https://www.accessengineeringlibrary.com/content/book/9780071742474 Free files (CC BY 4.0, Xem Studio; STEP + STL, 2 parts): https://xemstudio.com/files/hardware/sanitary-clamp-bolted-clamps-10-12in/index.json API: https://xemstudio.com/api/geometry?object=sanitary-clamp-bolted-clamps-10-12in