Library › Hardware › Heat transfer ·
Annular wire-mesh screen ring: 100 mesh, Ø47.5 / Ø41.5, for a 2 in tube
What annular screen ring fits a 2 inch tri-clamp spool? · Hardware · basis: Urieli & Berchowitz screen relations: porosity 1 − π m d / 4, hydraulic diameter d·β/(1 − β); heat transfer and friction from Gedeon & Wood (1996)
Also called: annular regenerator screens, stirling regenerator mesh ring, 100 mesh regenerator
Long Earth Society build part. The regenerator of my free-piston generator. Long Earth Society
Exact dimensions. Every file is drawn at true size with no tolerance added. The holes and pins that meet another part are listed below under Mating features, with the fit each joint needs; open those by your process's clearance before making the part. Mating features
- sizes
- 5 in table
Notes
- 389 rings of 100 mesh, 0.1 mm wire screen stacked 77.8 mm high in the annulus between the liner (Ø41.5) and the hot spool's bore (Ø47.5), on the liner's spokes and under its rim.
- Porosity 0.691, hydraulic diameter 0.223 mm, frontal area 419 mm². At the design point the regenerator's NTU is 165 (effectiveness 0.9940), its enthalpy loss 5.4 W.
- Stack the rings with the weave of each layer turned a little against the last; fill the annulus exactly, so the rim holds the stack.
Annular wire-mesh screen ring: 100 mesh, Ø47.5 / Ø41.5, for a 2 in… size chart
| feature | value |
|---|---|
| ring | Ø47.5 / Ø41.5 × 0.2 |
| count | 389 |
| screen | 100 mesh, 0.1 mm wire |
| porosity | 0.691 |
| hydraulic Ø mm | 0.223 |
Mating features
Drawn at the exact size. Open press, slide, run and socket features by your process's clearance (tolerances by process); leave designed gaps and clamp fits as drawn.
| feature | exact | mates with | fit | files |
|---|---|---|---|---|
| OD | Ø47.5 | hot spool bore | slide | all |
| ID | Ø41.5 | liner tube OD | slide | all |
Where the files are
Other publishers' files are linked, not hosted. "verify" = check the license at the link before commercial use.
| Ohio University (Urieli) | Stirling cycle machine analysis: ideal adiabatic and simple analysis (after Urieli & Berchowitz, Stirling Cycle Engine Analysis, 1984) | web | author's site |
| NASA (NTRS, public domain) | Gedeon & Wood (1996), Oscillating-flow regenerator test rig: correlations for screens and felts, NASA CR-198442 (f = 129/Re + 2.91 Re^-0.103; Nu = (1 + 0.99 Pe^0.66) β^1.79) | US Government work, public domain | |
| Long Earth Society | Engine builds | web, video | LES site |
Free files
★ Free files 1 parts. Xem Studio design: free to use, print and sell things from; not to be republished as files. Xem Studio Design License. index.json
Use this part in your AI. Your AI gets the exact sizes and files straight from Xem and can design a mount, case or adapter around it. Direct downloads here are limited to one file every 10 minutes; through your AI they are unlimited.
Connect Xem to your AI (free, no account, about a minute)
https://xemstudio.com/mcp- Claude: Add to Claude
- ChatGPT (Plus or higher): open Connectors → Advanced → turn on Developer mode → Create → paste the address, no authentication → Create.
- Cursor: install with one click. VS Code: install with one click.
| regen-ring-41.5x47.5x0.2 | regenerator ring: one layer of 100 mesh woven screen (0.1 mm wire) cut to Ø47.5 / Ø41.5, drawn 0.2 thick (two wire diameters) | STEP · STL |
https://xemstudio.com/mcp to Claude, ChatGPT, Cursor or any MCP client (free, no account, one minute) and it can look up exact sizes, mating fits and free STEP/STL from every chat.Plain text: sheet.txt · JSON: /api/geometry?object=annular-wire-screen-ring-2in

Fits with
Questions
Why 100 mesh?
At 40–50 Hz in helium the gas needs a fine matrix to give up and take back its heat each stroke; 100 mesh keeps the effectiveness above 0.99 while the friction stays a fraction of the cycle's work.