Library › Hardware › Diaphragms & membranes ·

Tri-clamp diaphragm membranes, flat, 1.5 and 2 in

What flat membrane clamps in a tri-clamp joint? · Hardware · basis: ISO 2852 Type B gasket section for the clamped ring (web 1.7, bulges on the groove diameter, 5.5 overall), ASME BPE bore for the free span; free-span thickness and stretch are design values

Also called: tri clamp diaphragm membrane, stirling diaphragm size, diaphragm swept volume, diaphragm membrane 2 inch, membrane gasket tri clamp

Used in Long Earth Society builds. Piezoelectric diaphragm

Exact dimensions. Every file is drawn at true size with no tolerance added. The holes and pins that meet another part are listed below under Mating features, with the fit each joint needs; open those by your process's clearance before making the part. Mating features

sizes
2 in table

Notes

  • The membrane is drawn flat, as it sits at mid-stroke. Outside the bore it has the Type B gasket section, so it is clamped like a gasket: web 1.7 from the bore out to flange − 1 with a bulge each side on the groove diameter (Ø43.5 / Ø56.5), 5.5 over both, squeezed 0.3 into each face's groove as a gasket is. Inside the bore it is a 1.0 mm free span.
  • Free span: from the centre-disc edge to the bore, 8.90 mm (1.5 in, Ø17 disc) and 13.75 mm (2 in, Ø20 disc). At the design stroke the span forms a cone of 29.3° / 28.6° and stretches 14.7 / 13.9 %.
  • Swept volume with a rigid centre disc is the frustum between the disc edge and the bore: V = s · π/3 · (R² + R r + r²); see the table.
  • Three Ø2.4 holes for the M2 screws that clamp the centre and backing discs.

Tri-clamp diaphragm membranes, flat, 1.5 and 2 in size chart

size (in)od (mm)bulge on dia (mm)free span dia (mm)free t (mm)overall (mm)web (mm)disc dia (mm)annulus (mm)stroke (mm)cone (°)stretch pctswept (ml)
263.056.547.51.05.51.720.013.7515.028.613.914.16
1.549.543.534.81.05.51.717.08.910.029.314.75.48

Mating features

Drawn at the exact size. Open press, slide, run and socket features by your process's clearance (tolerances by process); leave designed gaps and clamp fits as drawn.

featureexactmates withfitfiles
bulgesType B: web 1.7, bulges on Ø43.5 / Ø56.5, 5.5 overallgasket grooves of the ferrule and the head (0.3 squeeze each)clampmembrane-*
web1.7between the two landsclampmembrane-*
free spanØ34.8 / Ø47.5 × 1.0moves with the centre discdesignedmembrane-*
screw holes3 × Ø2.4M2 screwsdesignedmembrane-*

Where the files are

Other publishers' files are linked, not hosted. "verify" = check the license at the link before commercial use.

ISO (via iTeh sample)ISO 2852 clamp liners: face profile and flange / groove diametersPDFstandard excerpt; dimensions are facts
ASMEBPE Bioprocessing Equipment (clamp fitting dimensions, tube OD and wall)standardASME; dimensions are facts verify
Long Earth SocietyEngine buildsweb, videoLES site

Free files

★ Free files 2 parts. Xem Studio design: free to use, print and sell things from; not to be republished as files. Xem Studio Design License. index.json

Use this part in your AI. Your AI gets the exact sizes and files straight from Xem and can design a mount, case or adapter around it. Direct downloads here are limited to one file every 10 minutes; through your AI they are unlimited.

Connect Xem to your AI (free, no account, about a minute)
https://xemstudio.com/mcp
  1. Claude: Add to Claude
  2. ChatGPT (Plus or higher): open Connectors → Advanced → turn on Developer mode → Create → paste the address, no authentication → Create.
  3. Cursor: install with one click. VS Code: install with one click.
Other apps and full steps
membrane-2in2 in flat membrane: Ø63 OD, web 1.7 from the bore out with a Type B bulge each side on Ø56.5 (5.5 overall), free span Ø47.5 × 1.0, 3 × Ø2.4 on Ø13STEP · STL
membrane-1.5in1.5 in flat membrane: Ø49.5 OD, web 1.7 from the bore out with a Type B bulge each side on Ø43.5 (5.5 overall), free span Ø34.8 × 1.0, 3 × Ø2.4 on Ø12STEP · STL
Let your AI pull this. Add https://xemstudio.com/mcp to Claude, ChatGPT, Cursor or any MCP client (free, no account, one minute) and it can look up exact sizes, mating fits and free STEP/STL from every chat.
Set it up →

Plain text: sheet.txt · JSON: /api/geometry?object=tri-clamp-diaphragm-membrane

Tri-clamp diaphragm membranes, flat, 1.5 and 2 in, isometric render of a generated part
Render of membrane-1.5in from the free STEP; not to scale.

Fits with

Questions

How much volume does a 2 in tri-clamp diaphragm sweep?

14.16 mL at 15 mm stroke with the Ø20 centre disc (frustum between Ø20 and Ø47.5).

Why is the membrane drawn flat?

That is its shape at mid-stroke; at the ends of the stroke the free span is a shallow cone either side.